Master’S Thesis: Phase-Contrast X-Ray Imaging Of Advanced Semiconductor Packages
- Location: Sweden
- Workplace: Hybrid
- Job type: Other
- Salary: SEK15000-30000/month
- Posted: Posted
- Evaluates X-ray phase-contrast imaging for semiconductor packages
- Requires master's student in physics, electrical engineering or applied math
- Python programming and basic X-ray physics knowledge needed
- At least 50% on-site in Kista, working language English
- Compensation SEK 15,000 halfway and 15,000 upon completion
Do you want to help reveal what conventional X-ray imaging cannot see? Excillum develops the world’s brightest laboratory X-ray sources, and we are looking for a master’s student in physics, electrical engineering, applied mathematics or a similar field who is excited about X-ray phase-contrast imaging, advanced semiconductor packaging and experimentation.
About Excillum
At Excillum, we push the boundaries of X-ray technology to enable breakthroughs in manufacturing, medicine and science. Our advanced X-ray sources enhance the manufacturing of semiconductors, batteries, electronics and aerospace components, as well as enable new biomedical and material sciences. They make our customers’ X-ray systems faster and better with lower cost of operation.
Founded in 2007 by researchers from KTH, Excillum has grown into a global leader in advanced microfocus and nanofocus X-ray sources. Today, our products are used by leading industrial companies, instrument manufacturers and research institutions around the world.
About the project
X-ray phase-contrast imaging can improve the visibility of low-density features that produce weak absorption contrast. Used in fields such as medical soft-tissue imaging and materials science, it exploits phase shifts caused by the refractive index of different materials in the sample, complementing conventional absorption-based contrast.
Advanced packaging is a key technique improving the performance of modern electronic components. Next-generation high-end chips incorporate co-packaged optics, silicon photonics and waveguides for data transmission, as well as glass substrates. Thermal-interface materials are another important type of low-density feature in advanced packages. Non-destructive inspection of these structures remains challenging, and high-resolution phase-contrast imaging may offer a solution. However, metal layers and interconnects can strongly attenuate the low-energy X-rays required for phase contrast, creating a trade-off between sensitivity to low-density features and penetration through the package.
This thesis will evaluate the feasibility of using 3D X-ray phase-contrast imaging with nano-CT and/or laminography to inspect low-density structures in advanced electronic packages. Simulations will first assess feasibility and optimise our in-house imaging system. The most promising conditions will then be tested in a proof-of-concept experiment, with the possibility to perform further measurements if time permits.
What you will do
Review the benefits and limitations of different X-ray phase-contrast imaging methods
Simulate representative phase-contrast imaging use cases for electronic packages using our in-house simulation software
Optimise key imaging parameters, including the X-ray spectrum, detector and scan geometry
Validate the selected conditions experimentally
If time permits, compare different target materials
If time permits, evaluate different detectors
What you will learn
X-ray imaging and CT
Phase contrast imaging
Image simulation
Practical work with advanced laboratory instruments
Who you are
You are a master’s student in physics, electrical engineering, applied mathematics or a similar field, with a genuine interest in X-ray physics and simulation. You enjoy turning physics into models, and models into tools that others can use. To succeed in this project, we believe you have:
Programming skills in Python
Basic knowledge of X-ray physics and imaging
Good communication skills in English
It is a strong merit if you have knowledge of X-ray imaging, CT, phase contrast or image simulation.
Practical information
Level: Master’s thesis, 30 credits
Start: Early 2027
Location: Excillum, Jan Stenbecks torg 17, Kista – at least 50% on-site
Working language: English
Supervisors: Jenny Romell & Till Dreier
Project owner: Till Dreier
Compensation: SEK 15,000 halfway through the project and an additional SEK 15,000 upon successful completion. Excillum also covers project-related expenses such as travel and materials. Note that compensation can only be paid to students with a valid work permit in Sweden.
Apply
To apply, please submit your CV, a cover letter and a copy of your academic transcripts.
We look forward to your application! If you have any questions regarding the thesis, do not hesitate to contact Hugo Högberg West at [email protected].
About Excillum
Excillum is a leading company in the field of high-end microfocus and nanofocus X-ray sources. Excillum was founded in 2007 by researchers from the Royal Institute of Technology (KTH) Stockholm, Sweden. The first product was market released in 2010, the MetalJet. Our mission is to enable new science, improve medicine and enhance manufacturing by continuos development of state-of-the-art X-ray sources.
About the job
Location
Job type
OtherWorkplace
HybridExperience
EntryDepartment
Thesis ProjectsFirst posted on
Salary
SEK15000-30000/monthTech stack
The source for X-ray innovation
Company size
51-200 employees
Founded in
2007
Industry
Industrial Machinery Manufacturing
Headquarters
Stockholm, Stockholm County